FUZ SHIN
220v 75kw Hight Starting Torque Frequency Inverter
220v 75kw Hight Starting Torque Frequency Inverter
Adapted motor: 220V-240V 75kw 100hp 3 phase asynchronous motor(without capacitor and resistor).
Frequency Inverter Driver input frequency 47-63HZ; Output 0-500HZ adjustable.
Starting torque 180% at 0.5HZ.
16 speeds and running time can be preset and automatically switching over.
Inbuilt DC braking.
inbuilt PID.
Modbus RS485 Port.
5 programmable digital inputs, 1 Pulse input; 2 analog inputs.
1 digital output, 1 pulse output, 1 analog output, 1 relay output.
Control Mode |
Open loop vector control(SVC) V/F control Torque control |
Starting Torque |
0.5Hz/180%(SVC) ; |
Speed adjusting range |
1:200(SVC); 1: 1000(FVC); 1: 50(V/F) |
Speed control accuracy |
±0.5%(SVC) ±0.02%(FVC) |
Torque control accuracy |
±5%(FVC) |
Overload Capability |
150% rated current 60s, 180% rated current 3s. |
Torque boost |
automatic torque boost; manual torque boost 0.1%~30.0%. |
V/F curve |
Three types are available:liner; Multi-point type; N times square(1.2 times square, 1.4 times square,1.6 times square,1.8 times square,2 times square). |
DC brake |
DC brake frequency:0.00Hz~Max. frequency; Braking time: 0.0s-36.0s; Braking current:0.0%-100.0%. |
JOG control |
JOG frequency range:0.00Hz-50.00Hz; JOG ACC./DCC time 0.0s-6500.0s. |
Multi step speed control |
16 steps speed can be set. |
In built PID |
can realize close loop process control for pressure, temperature, flow etc. |
Automatic voltage regulation |
can output constant voltage even grid voltage fluctuates. |
safety detection to Peripherals |
Safety detection to Peripherals when power on(such as grounding, shortcut etc.) |
Textile swing control |
Triangular wave frequency control function |
Timing control |
setting range 0H-65535H |
Run/Stop command giving |
keypad giving,terminals giving,RS485 giving. |
Running Frequency source |
digital giving, analog voltage giving, analog current giving, impulse giving, RS485 giving. |
Input terminals |
Five digital inputs,one of which can be used set as high speed pulse input, the Max. Frequency can reach 100kHz. Source PNP or NPN input. Two analog inputs. |
Output terminals |
One high speed pulse output (which can be set into open circuit collector output), 0kHz~100kHz square wave output; one digital output; one Relay output; one analog output,0mA-20mA or 0v-10V selectable. |
Protection function |
motor shortcut detection,input output phase lost protection, over current protection, over voltage protection, low voltage protection, over heat protection, over load protection. |